. S04-600X Digital Microscope User Manual repared by oolingtech Engineering Dept. 2011.10.1 1/28. Jewelry & coin (Collections) inspection 9. Visual Assistance 10.
Others Digital Microscope(S04-600X) must be connected to the computer,User interface is very friendly and you can do the Measure work easily. You can find more information of the product on this manual. oolingTech Parts of Microscope ① ② ③ ④ ⑤ ⑥ ⑦ ① LED Light ② Lens ③Magnification 25X600X ④ Focus Roller ⑤ SNAP & Zoom Switch ⑥ Body ⑦ USB Line Specification Image CMOS Sensor Controller High Speed DSP (Driver Free available) Focus Range 0mm 40mm Snap Shot Software and Hardware Video Capture Resolution 1.3M. oolingTech Power Supply USB Port ( 5V DC ) USB 2.0 & USB 1.1 Compatible Operation System Windows XP, Vista, Win 7 32 bit and 64 bit. Language: English, Chinese and other language by selection System Requirement: Pentium Computer with 700M Hz & above, 20M HD Space CD ROM Driver, 64MB RAM, Direct X VGA Card CD disk Driver and Micro-Measurement Tool Product dimension 112 mm ( L ) X 33 mm ( R ). USB1.1.
How to install the Driver S04-600X Digital Microscope is a free Driver Product, it can works immediately after being connected to the computer with operation system above win2000 version. Connect the Digital Microscope by USB2.0 cable to your computer, Double-click ‘my computer’. oolingTech 1.
Driver installation 1Click to continue, the screen will show the installation progress. oolingTech Click “next” to continue,as followings: Click “next” to continue,as followings: 7/28. oolingTech Click “continue Anyway”, as followings: Click “Finish” to continue,as followings 8/28. oolingTech Select ’Yes, I want to restart my computer now’, and click “finish”. After restart your computer, Plug-in the USB port of Digital Microscope into Computer USB port. Following the user guide by steps and complete by click “Next” - “Continue anyway” - “Finish”. oolingTech When Drive are installed, icon will appear on the desktop.
Double-click it 10/28. oolingTech 6 Interface ` T oolbar Preview Area 11/28. oolingTech 7 Tool bar instroduction 1 Click 'Set capture This equipment has video and photo function. Before video and photo Please click file folder path' 'Set snapshot file path' to set the file storage area. 2 Click You can select the different equipment according to your request if your computer has two video equipment or more 3 Click 1 Click“Video capture filter”. oolingTech Video parameters setting,you can change some values according to your request, Do not recommend to make some changes because the parameters has been adjusted to best form before leaving factory If the values are changed negligently,and click 'default' to recover the factory shipped state. oolingTech For example: “Object tracking ” “ Scale” in the yellow form 2 Click “video capture pin.” You can set the different output size according to your request 4 Click Photo and Video setting 14/28.
oolingTech “Still Image capture” “still capture Size” Select Video Format AVI。 15/28. oolingTech 2 Measurement installations: 1 Click to continue, as followings 16/28.
oolingTech 2 Click “next” to continue, as followings 3. Click “next” to continue, as followings 17/28. oolingTech 4. Click “next” to continue, as followings 5.
Click “next” to continue, as followings 6 Click “Install” to continue, as followings 18/28. oolingTech Wait a few seconds while the installation taking place. 7.Click “Finish” and the installation completes. oolingTech 8.After the installation completes, double click at computer desktop to start using the software. Plug-in the devices, Display in operation window 20/28. oolingTech 9 Click,open the operation system Choose the Image resolution from 320.240 to 1600.1200, default at VGA Mode640.480 10 Click to use measurement function. oolingTech 11 Click to open pictures, and click to save pictures Video PLAY(Pause),STOP Image Parameter including Image setting and special effects 22/28.
oolingTech Magnifier 16 Click Ruller, as followings 17 Click start calibration make sure certain accuracy. Our experience told us that measurement could be controlled at 99% high precision. Measure tolerance could be caused from human eye distortion and defocus. More practice is helpful to measurements. oolingTech 18 Key in the Measure data(Pixel),Unit, and Click’ OK’ Warning: Please do calibration again once Magnification Ratio changed. Color setting of display character 24/28. oolingTech 20 Click to export word or excel format.
Example: Measure data under word file From Left to right: Line ring Square Polygon Set-line Length Oval Point to Point distance Point to Line distance Parallel line Angle (as below show) 25/28. oolingTech For example 1 Line measurement: For example 2 26/28. oolingTech Rectangular measurements: For example3 Ring measurements: For example 4 Arc measurements: 27/28.
oolingTech 3Please click to Continue when the NET Framework 2.0 is necessary, and you must install the application “Instmsia.exe” of disk if your computer operation system is MAC OS.
Learn more. The Plugable USB2-Micro-200X USB microscope provides up to 50X magnification optically and up to 200x and can be used on computers running Windows, Mac OS X, or Linux simply by plugging it into a spare USB 2.0 port and it requires no external power. It operates like a standard webcam and can be used with the default webcam software included in your computer’s operating system. Setup and Drivers Since our microscope uses a standard webcam chipset, it will automatically install default webcam drivers when plugged in to a computer. It can be used with any webcam app, like the camera app built in to Windows 8.1, Photo Booth in OSX, or a third party program like VLC media player. We also have custom Windows and OSX software designed specifically to work with the microscope. The download for this can be found below: Windows: Mac OSX: Raspberry Pi running Raspbian:.NOTE: Working with the current version of Raspian Jessie.
We have tested our Microscope with Linux using by using the following terminal commands: “sudo apt-get install guvcview” “guvcview” Frequently Asked Questions Q: How do I zoom in on an object? A: The level of magnification is controlled by the silver focus wheel, then the microscope or the object must be moved to the appropriate distance in order to be in focus. Q: I can’t get my microscope to zoom past 30x indicated magnification, how do i get to 200x? A: At the closest distance with the clear shield touching the object, there are two possible magnifications. The first is at around 30x indicated, but if you continue to rotate the focus wheel, the image will get blurry, then sharp again at around 200x indicated! Q: How do I dim the LED lights?
A: The LED lights can be dimmed or turned off by rotating the black LED light control wheel near the rear of the microscope. If you are having problems with glare, try viewing your intended object at an angle. Q: I see a “device not detected” message in MicroCapture when it’s clearly connected. A: You may have to disconnect and reconnect the microscope when restarting MicroCapture, and it can take up to 30 seconds for MicroCapture to detect the microscope. It’s also possible that the microscope isn’t running under it’s specialized driver that MicroCapture requires in order to see the microscope. If none of this helps, please contact us at support@plugable.com and we can help troubleshoot the issue.